KNOWN RESTRICTIONS AND LIMITATIONS
10/24/01 P/N: 9038090-17 CUSTOMER RELEASE NOTES Page: 23 of 34
F0615-F Subject to Change Without Notice
Link-Aggregation Control Protocol (LACP) I.D.
If a line card containing an LACP SmartTRUNK is hot-swapped out and then back in, the
SmartTRUNK will not recover.
F1654
Open Shortest Pathway First (OSPF) I.D.
OSPF incorrectly allows the entry of numeric interface names. Numerically defined OSPF interfaces
are interpreted as IP addresses, and are not valid.
F0879
When adding interfaces to OSPF using the ospf add interface command, no function currently
exists to determine whether the interface name is valid; therefore no warning message will appear
upon the entry of an invalid interface name.
F1461
Point to Point Protocol (PPP) I.D.
When creating an IP interface on a VLAN with a single PPP port configured, the interface should be
set to parameter type point-to-point.
07757
Port-Mirroring I.D.
When a T-series card is used in an X-Pedition router, the first two octets in the source MAC field of
some mirror output packets may appear to be corrupted. This is due to a known issue with T-series
cards that modifies the source MAC of any unlearned packets, and corruption will cease once the
flow has been learned.
Normal switching and routing, excluding Layer-4 bridging in flow-based mode, will not be affected by
this error.
H0007
If large numbers of flows exist on an ER16 during the addition of a port-mirroring command to the
configuration, the console may appear to freeze; it may take 5 minutes or more to modify all flows
for a single port-mirror command.
F1043
Power On Self-Test (POST) I.D.
Entering the system set poweron-selftest quick command in the ER16’s configuration causes the
system to display the following errors during "DIAG BOOT TEST":
%DDT-E-MEMORY_ALIASING, Memory error @ 0x70000000 ; Possible aliasing with: 0x70800000
%DDT-E-MEMORY_ALIASING, Memory error @ 0x70000004 ; Possible aliasing with: 0x70800004
%DDT-E-MEMORY_ALIASING, Memory error @ 0x70000008 ; Possible aliasing with: 0x70800008
%DDT-I-MEM_MAX_ERRORS, Max Errors Reached; Suppressing further errors for this test
%DDT-I-MEM_INFO, $Memory Failure : SOPP Memory MAIN DRAM [16775168 bytes]
%DDT-E-SOPP_MEM_TEST, (Slot 5) : SOPP Memory Test : FAILED
%DDT-E-GE_MODULE, GE Module (Slot 5) : FAILED
These errors are incorrect and should be ignored.
F0619
Quality of Service (QoS) I.D.
The interface name parameter, which is the last parameter when configuring an IPX QoS entry,
does not work. Do not enter an interface name when configuring an IPX QoS entry.
F1673