ISSUES RESOLVED IN E8.2.1.1
10/24/01 P/N: 9038090-17 CUSTOMER RELEASE NOTES Page: 14 of 34
F0615-F Subject to Change Without Notice
Multicast I.D.
The workaround for multicast across Q-trunks in pre-“T-serieshardware has been restored. See
tech bulletin TK609-1 for more information. This issue originally appeared in E8.1.0.1, and was
resolved in E8.1.0.12.
F1685
Multicast streams on line cards using OCMAC and GMAC chips incorrectly age out every Layer-2
aging period.
F1818
When running IGMP and/or DVMRP on a SmartTRUNKed interface, multicast traffic will stop after
260 seconds.
F1871
Network Address Translation (NAT) I.D.
The X-Pedition may core dump when NAT is dynamic and/or overloaded. This issue was resolved in
E8.2.0.4.
01534
01652
Open Shortest Path First (OSPF) I.D.
The configuration of Point-to-Multipoint interfaces will cause OSPF to remain in the “2-way” state.
This issue occurs with many Frame Relay OSPF configurations. This issue was resolved in
E8.1.0.7.
F1449
Port I.D.
If the ifg sub-option is included in the port set <port#>|<all-ports> command, or entered after
previous port set <port#>|<all-ports> commands have been included in the X-Pedition’s
configuration, this sub-option will error the command line and disallow the line from being negated
from the configuration. This issue was resolved in E8.1.0.9.
00617
01087
01345
Port-Mirroring I.D.
When port-mirroring is configured, the monitor port will receive multiple copies of the same multicast
packets. This issue was resolved in E8.1.0.7.
F1017
When mirroring under Layer-4 bridging mode, traffic matching an ACL may not be copied out of the
destination ports if the ACL is applied to the inbound ports. Negating a mirroring command will also
disable other configured mirrors. In rare cases, X-Pedition will core dump when a mirroring
command is saved. This issue was resolved in E8.2.0.1.
F1527
When mirroring traffic from a port with Layer-4 bridging enabled, the X-Pedition may core dump. F1591
When an X-Pedition is routing, and port-mirroring is included in the startup configuration, packets
received by the source ports fail to be mirrored after reboot. This issue originally appeared in
E8.2.0.1, and was resolved in E8.2.0.2.
F1625
Huntgroup SmartTRUNKs may temporarily lose connectivity when port-mirroring is configured on
multiple source ports. Enterasys Networks recommends that no more than 8 source ports are