Security Configuration Command Set
Configuring VLAN Authorization (RFC 3580)
11-32 SecureStack B2 Configuration Guide
11.3.3.3 clear vlanauthorization
Return port(s) to default configuration (vlanauthrization disabled, egress untagged).
clear vlanauthorization [port_str]
Syntax Description
Command Mode
Read-Write.
Command Defaults
If no port string is entered, all ports across the stack will be reset to default
configuration with vlanauthrization disabled and egress frames untagged.
Example
This example show how to clear vlan authentication for all ports on slots 3, 4, and 5:
port_str (optional) Specifies which ports are to be restored to
default configuration. If no port string is entered, the the
action will be a global setting. For a detailed description
of possible port-string values, refer to Section 3.1.1.
clear vlanauthorization ge.3-5.*