Differentiated Services Configuration Command Set
Creating Diffserv Classes and Matching Conditions
7-6 SecureStack B2 Configuration Guide
7.3.2.2 show diffserv class
Use this command to display information about Diffserv classes.
show diffserv class {summary | detailed classname}
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Only.
Example
This example shows how to display a summary of Diffserv class information. In this case, there are
two classes configured, named “guest” and “admin”:
summary Displays a summary of Diffserv class information.
detailed
classname
Displays detailed Diffserv information for a specific class.
B2(rw)->show diffserv class summary
Class Name Class Type Ref Class Name
----------------- ------------ -------------------------------
guest All
admin All