VLAN Configuration Command Set
Configuring the VLAN Egress List
SecureStack B2 Configuration Guide 6-23
6.3.4.2 set vlan forbidden
Use this command to prevent one or more ports from participating in a VLAN. This setting instructs
the device to ignore dynamic requests (either through GVRP or dynamic egress) for the port to join
the VLAN.
set vlan forbidden vlan-id port-string
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows you how to set fe.1.3 to forbidden for VLAN 6:
vlan-id Specifies the VLAN for which to set forbidden port(s).
port-string Specifies the port(s) to set as forbidden for the specified
vlan-id.
B2(rw)->set vlan forbidden 6 fe.1.3