show multiauth port
Enterasys D-Series CLI Reference 17-37
Example
Thisexampleshowshowtoclearthemultipleauthenticationprecedence:
D2(rw)->clear multiauth precedence
show multiauth port
Usethiscommandtodisplaymultipleauthenticationpropertiesforoneormoreports.
Syntax
show multiauth port [port-string]
Parameters
Defaults
Ifport‐stringisnotspecified,multipleauthenticationinformationwillbedisplayedforallports.
Mode
Switchcommand,read‐only.
Example
Thisexampleshowshowtodisplaymultipleau thenticationinformationforportsge.3.1‐4:
D2(rw)->show multiauth port ge.3.1-4
Port Mode Max Allowed Current
users users users
------------ ------------ ---------- ---------- ----------
ge.3.1 auth-opt 8 8 0
ge.3.2 auth-opt 8 8 0
ge.3.3 auth-opt 8 8 0
ge.3.4 auth-opt 8 8 0
set multiauth port
Usethiscommandtosetmultipleauthenticationpropertiesforoneormoreports.
Syntax
set multiauth port mode {auth-opt | auth-reqd | force-auth | force-unauth} |
numusers numusers port-string
port‐string (Optional)Displaysmultipleauthenti cati oninformationforspecificport(s).