Enterasys® SecureStack™ C3Gigabit Ethernet SwitchesHardware Installation GuideC3G124-24C3G124-48P/N 9034276-017.5x9-inch cover with bleed on 4 sides
viii 3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateandfederalcourtsoftheCommonwealthofMas
ix8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramareofcriticalvaluetoEnterasysand,ac
x
xiContentsAbout This GuideWho Should Use This Guide ...
xiiConnecting AC and RPS-SYS Power ...3-15AC Power ...
xiiiFigures1-1 C3G124-24 Stackable Switch ...1-21-2 C3G12
SecureStack C3 Installation Guide xvAbout This GuideThisguideprovidesanoverview,installationandtroubleshootinginstructions,andspecification
How to Use This Guidexvi About This GuideHow to Use This GuideReadthroughthisguidecompletelytofamiliarizeyourselfwithitscontentsandgainan
Conventions Used in This GuideSecureStack C3 Installation Guide xviiConventions Used in This Guide Thefollowingconventionsareusedinthisguide:N
Getting Helpxviii About This GuideGetting HelpForadditionalsupportrelatedtotheswitchesorthisdocument,contactEnterasys Networksusingoneof
SecureStack C3 Installation Guide 1-11IntroductionThischapterintroducestheC3G124‐24andC3G124‐48 st ackableswitches.OverviewTheC3G124‐24and
Overview1-2 Introduction•SFPslotsthatprovideyouwiththeoptionofinstallingSmallFormPluggable(SFP)Mini‐GBICsfor1000BASE‐SX/LXfiber‐optic
OverviewSecureStack C3 Installation Guide 1-3Figure 1-2 C3G124-48 Stackable SwitchHigh-Speed Stack ConnectionsTheswitcheshaverear‐panelconnector
Connectivity1-4 IntroductionConnectivityTheswitchconnectstoEthernetnetworksorworkstationsviathefixedfrontpanelRJ45connectorsandfourup
Standards CompatibilitySecureStack C3 Installation Guide 1-5Switch Configuration Using CLI CommandsTheCLIcommandsenableyoutoperformmorecomple
LANVIEW Diagnostic LEDs1-6 Introduction
SecureStack C3 Installation Guide 2-12Network RequirementsBeforeinstallingthedevice,reviewtherequirementsandspecificationsinthischapter.1
100BASE-TX Network2-2 Network Requirements100BASE-TX NetworkWhenconnectinga100BASE‐TXsegmenttooneofthefixedports(1 through24onC3G124‐24,
SecureStack C3 Installation Guide 3-13Hardware InstallationThischapterprovidesinstructionstoinstalltheC3G124 ‐24andC3G124‐48.Unlessotherwi
iNoticeEnterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthisdocumentanditswebsitewitho
Considerations Prior to Installation3-2 Hardware InstallationConsiderations Prior to InstallationWheninstallingtheswitch,notethefollowing:•Befor
Installing Optional Mini-GBICsSecureStack C3 Installation Guide 3-3Installing Optional Mini-GBICs ThissectiondescribeshowtoinstallMini‐GBICsin
Installing Optional Mini-GBICs3-4 Hardware InstallationInstallationToinstallaMini‐GBICthathasanMT‐RJconnector,refertoFigure 3‐3,orforaM
Installing Optional Mini-GBICsSecureStack C3 Installation Guide 3-5Figure 3-4 Mini-GBIC with LC ConnectorRemoving the Mini-GBICToremoveaMini‐GBIC
Installing the Switch on a Flat Surface3-6 Hardware Installation2. Removethe cablesconnectedtotheMini‐GBIC.3. Locatethereleasetabunderthef
Installing the Switch on a Flat SurfaceSecureStack C3 Installation Guide 3-7Figure 3-5 Chassis Bottom, Rubber Feet Placement4. Removethe protectiv
Installing the Switch on a Flat Surface3-8 Hardware InstallationIfyouareinstallingseveralswitchesinastack,proceedto“ConnectingHigh‐SpeedS
Rack Mounting the SwitchSecureStack C3 Installation Guide 3-9Rack Mounting the Switch Toinstalltheswitch ina19‐inchrack,youneed:•Tworackmo
Rack Mounting the Switch3-10 Hardware InstallationAttaching Brackets and Installing in RackProceedasfollowstoinstalltheswitchintoa19‐inchrac
Connecting High-Speed Stacking CablesSecureStack C3 Installation Guide 3-11Connecting High-Speed Stacking CablesThestackofswitchescanbeconnecte
ii REGULATORY COMPLIANCE INFORMATIONFEDERAL COMMUNICATIONS COMMISSION (FCC) NOTICEThisdevicecomplieswithPart15oftheFCCrules.Operationissub
Configuring Switches in a Stack3-12 Hardware InstallationFigure 3-9 High-Speed Stacking Cable ConnectionsAfterconnectingthecablestothestacking
Configuring Switches in a StackSecureStack C3 Installation Guide 3-13Onceinstalledinastack,theswitchesbehaveandperformasasingleswitch.A
Configuring Switches in a Stack3-14 Hardware InstallationRecommended Procedures for New and Existing StacksInstalling a New Stackable System of Up to
Connecting AC and RPS-SYS PowerSecureStack C3 Installation Guide 3-15Adding a New Switch to an Existing StackUsethefollowingproceduretoinstalla
Connecting AC and RPS-SYS Power3-16 Hardware InstallationFigure 3-10 Switch Rear View3. ObservethatthepowerCPULED(notshown),locatedonthefr
Connecting AC and RPS-SYS PowerSecureStack C3 Installation Guide 3-17SecureStack Redundant Power SystemIfyouareinstallinganoptionalredundantpo
Connecting to Console Port for Local Management3-18 Hardware InstallationConnecting to Console Port for Local ManagementThissectiondescribeshowto
Connecting to Console Port for Local ManagementSecureStack C3 Installation Guide 3-19Figure 3-11 DB9 Male Console Port Pinout AssignmentsConnecting
Connecting to Console Port for Local Management3-20 Hardware InstallationFigure 3-12 Connecting an IBM PC or CompatibleConnecting to a VT Series Term
Connecting to Console Port for Local ManagementSecureStack C3 Installation Guide 3-21Figure 3-13 Connecting a VT Series TerminalConnecting to a Mode
iiiELECTROMAGNETIC COMPATIBILITY (EMC)Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,EN61000‐3‐2,
Connecting to the Network3-22 Hardware InstallationFigure 3-14 Connecting to a ModemConnecting to the NetworkThefollowingprocedurescoverthecable
Connecting to the NetworkSecureStack C3 Installation Guide 3-232. Connectthetwistedpairsegmenttotheswi tchbyinsertingtheRJ45connectoron
Connecting to the Network3-24 Hardware InstallationRepeatallstepsaboveuntilallconnectionshavebeenmade.Figure 3-16 Four-Wire Crossover Cable
Connecting to the NetworkSecureStack C3 Installation Guide 3-25Figure 3-18 Eight-Wire Crossover Cable RJ45 Pinouts for 10/100/1000BASE-TXFigure 3-19
Connecting to the Network3-26 Hardware InstallationConnecting Fiber-Optic Cables to MT-RJ PortsThissectioncontainstheproceduresforconnectinga1
Connecting to the NetworkSecureStack C3 Installation Guide 3-27.2. InserttheMT‐RJcableconnectorintotheMT‐RJconnectoruntilitclicksintopla
Connecting to the Network3-28 Hardware Installation4. VerifythatalinkexistsbycheckingthattheportLink/ActivityLEDison(blinkinggreenors
Connecting to the NetworkSecureStack C3 Installation Guide 3-29Thetransmitstrandfromaswitchportconnectstothereceiveportofafiber‐opticG
Connecting to the Network3-30 Hardware InstallationFigure 3-21 Cable Connection to LC Fiber-Optic Connectors3. Plugtheotherendofthecableintot
Completing the InstallationSecureStack C3 Installation Guide 3-31Completing the InstallationAfterinstallingtheswitchandmakingtheconnectionsto
iv ѻѻક䇈ᯢк䰘ӊSupplement to Product Instructions ᳝↦᳝ᆇ⠽䋼ܗ㋴(Hazardous Substance) 䚼ӊৡ⿄(Parts) 䪙3E∲+J䬝&G݁Ӌ䫀&U⒈㘨㣃3%%⒈Ѡ㣃䝮3%&apo
Completing the Installation3-32 Hardware Installation
SecureStack C3 Installation Guide 4-14TroubleshootingThischapterprovidesinformationconcerningthefollowing:Thisdevicecontainsabatterythati
Using LANVIEW4-2 TroubleshootingUsing LANVIEWTheseswitchessupporttheEnterasys Networksbuilt‐inLANVIEWLEDvisualdiagnosticandstatusmonitorin
Using LANVIEWSecureStack C3 Installation Guide 4-3Table 4-3 LANVIEW LEDsLED Color State Recommended ActionCPU Off Power disconnected. If the LED rema
Using LANVIEW4-4 TroubleshootingUP Off No valid connection to switch stack down connector.1. Make sure the switch connected to the stack down connecto
Troubleshooting ChecklistSecureStack C3 Installation Guide 4-5Troubleshooting ChecklistIfthedeviceisnotworkingproperly,refertoTable 4‐4for
Troubleshooting Checklist4-6 TroubleshootingCannot contact the switch through in-band management.IP address not assigned. Refer to the SecureStack C3
Using the Reset SwitchSecureStack C3 Installation Guide 4-7Using the Reset SwitchIfyouforgettheswitchloginpassword,usetheResetswitchtores
Using the Reset Switch4-8 Troubleshooting
SecureStack C3 Installation Guide A-1ASpecificationsThisappendixprovidesinformationaboutthefollowing:Enterasys Networksreservestherighttoc
vVCCI NOTICEThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformationTechnologyEquipment(VCC
Switch SpecificationsA-2 SpecificationsC3G124-48RJ45ports 1 through 48 Forty-eight, 10BASE-T/100BASE-TX/1000BASE-T compliant ports with auto-sensing
Mini-GBIC Input/Output SpecificationsSecureStack C3 Installation Guide A-3Mini-GBIC Input/Output SpecificationsTheMini‐GigabitEthernetCard(Mini‐G
Gigabit Ethernet SpecificationsA-4 SpecificationsGigabit Ethernet SpecificationsThefollowingspecificat ionsfortheMini‐GBICsshowninTable A‐3th
Gigabit Ethernet SpecificationsSecureStack C3 Installation Guide A-5MGBIC-LC09 Specifications (1000BASE-LX)MGBIC-08 Specifications (1000BASE-ELX) Tab
Gigabit Ethernet SpecificationsA-6 SpecificationsMGBIC-02 Specifications (1000BASE-T)Table A-10 MGBIC-08 Operating RangeItem 1550 nm Range9 or 10 µm S
Console Port Pinout AssignmentsSecureStack C3 Installation Guide A-7Console Port Pinout AssignmentsTheConsoleportisaDB9serialcommunicationspo
Regulatory ComplianceA-8 Specifications
Index-1IndexNumerics1000BASE-SX/LX network connectionsrequirements for 2-21000BASE-Trequirements for 2-2100BASE-TXrequirements 2-210BASE-Tconnection 3
Index-2UTP 4-wire crossover cable 3-24UTP 4-wire straight-through cable 3-24UTP 8-wire crossover cable 3-25UTP 8-wire straight-through cable 3-25Power
vi DECLARATION OF CONFORMITYApplicationofCouncilDirective(s): 89/336/EEC73/23/EECManufacturer’sName: Enterasys Networks, Inc.Manufacturer’sAddres
viiENTERASYS NETWORKS, INC.FIRMWARE LICENSE AGREEMENTBEFOREOPENINGORUTILIZINGTHEENCLOSEDPRODUCT,CAREFULLYREADTHISLICENSEAGREEMENT.Thisdocum
Kommentare zu diesen Handbüchern