clear dhcp pool hardware-address
SecureStack B2 Configuration Guide 17-15
Defaults
Ifnotypeisspecified,Ethernetisassumed.
Mode
Switchcommand,readwrite.
Example
Thisexamplespecifies0001.f401.2710astheEthernetMACaddressforthemanualaddresspool
named“manual1.”Alternatively,theMACaddresscouldhavebeenteredas00:01:f4:01:27:10.
B2(rw)->set dhcp pool manual1 hardware-address 0001.f401.2710
clear dhcp pool hardware-address
UsethiscommandtoremovethehardwareaddressofaDHCPclientfromamanualbinding
addresspool.
Syntax
clear dhcp pool poolname hardware-address
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampledeletestheclienthardwareaddressfromtheaddresspoolnamed“manual1.”
B2(rw)->clear dhcp pool manual1 hardware-address
set dhcp pool host
UsethiscommandtoconfigureanIPaddressandnetworkmaskforamanualDHCPbinding.
Syntax
set dhcp pool poolname host ip-address [mask | prefix-length]
Parameters
poolname Specifiesthenameoftheaddresspool.Poolnamesmaybeupto31
charactersinlength.
poolname Specifiesthenameoftheaddresspool.Poolnamesmaybeupto31
charactersinlength.
ipaddress SpecifiestheIPaddressformanualbinding.